100W Triple Output with PFC Function
Features :
TP-100
Universal AC input / Full range Built-in active PFC function, PF>0.94 Protections:Short circuit/Over load/Over voltage Free air cooling convection Fixed switching frequency at 100KHz 3 years warranty
series
..
SPECIFICATION
MODEL OUTPUT NUMBER DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER (max.) OUTPUT VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note.3 LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE POWER FACTOR (Typ.) INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER LOAD PROTECTION OVER VOLTAGE OVER TEMPERATURE(OPTION) WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE TP-100A CH1 5V 10A 3 ~ 15A 101W CH1: 4.75 ~ 5.5V 3.0% 1.0% 3.0% 7.0% 1.0% 6.0% 6.0% 1.0% 4.0% 3.0% 1.0% 3.0% 6.0% 1.0% 6.0% 6.0% 1.0% 4.0% 3.0% 1.0% 3.0% +10,-6% 1.0% 6.0% 6.0% 1.0% 4.0% 3.0% 1.0% 3.0% 8.0% 1.0% 6.0% 6.0% 1.0% 4.0% CH2 12V 4A 0.4 ~ 5A CH3 -5V 0.6A 0 ~ 1A TP-100B CH1 5V 10A 3 ~ 15A 105.2W CH2 12V 4A 0.4 ~ 5A CH3 -12V 0.6A 0 ~ 1A TP-100C CH1 5V 10A 3 ~ 15A 104W CH2 15V 3A 0.4 ~ 4A CH3 -15V 0.6A 0 ~ 1A TP-100D CH1 5V 10A 3 ~ 15A 105.2W CH2 24V 2A 0.4 ~ 3A CH3 12V 0.6A 0 ~ 1A
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 100mVp-p 100mVp-p 120mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p 100mVp-p 150mVp-p 100mVp-p
800ms, 60ms/230VAC 24ms/230VAC
Note.5 90 ~ 264VAC
800ms, 60ms/115VAC at full load
24ms/115VAC at full load 127 ~ 370VDC PF>0.98/115VAC at full load 78% 0.75A/230VAC 40A/230V 77% 78%
47 ~ 63Hz PF>0.94/230VAC 75% 1.5A/115VAC COLD START
<3.5mA / 240VAC 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed CH1:5.75 ~ 6.75V on +5V Protection type : Shut down o/p voltage, re-power on to recover 95 5 (TSW1) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -10 ~ +60 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.03%/ (0~50 ) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950-1, TUV EN60950-1 Approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1min.
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC SAFETY & ISOLATION RESISTANCE EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B EMC
(Note 4)
HARMONIC CURRENT EMS IMMUNITY MTBF DIMENSION PACKING
Compliance to EN61000-3-2,-3 Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, Light industry level, criteria A 170.1K hrs min. MIL-HDBK-217F (25 ) 199*99*50mm (L*W*H) 0.83Kg; 20pcs/17.6Kg/1.28CUFT
OTHERS
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
File Name:TP-100-SPEC 2006-08-22
100W Triple Output with PFC Function
Mechanical Specification
199 20 55 15 168 65
TP-100
Case No. 916A
series
Unit:mm
LED 9 8 7 6 5 4 3 2 1
+V ADJ.2 +V ADJ.1 2-M4
7.62
79
51 49.5 25 10 4-M4 L=6mm
6.15
5-M3 L=6mm
Terminal Pin No. Assignment :
Assignment Assignment Pin No. Pin No. AC/L DC OUTPUT V2 1 5 AC/N DC OUTPUT V1 2 6,7 FG DC OUTPUT COM 3 8,9 DC OUTPUT V3 4
25 117
Block Diagram
RECTIFIERS & FILTER RECTIFIERS & FILTER RECTIFIERS & FILTER DETECTION CIRCUT O.V.P. REGULATOR
fosc : 100KHz
V3 V2 +5V COM
I/P
EMI FILTER & RECTIFIERS
PFC CIRCUIT
POWER SWITCHING PWM & PFC CONTROL
FG
Derating Curve
Output Derating VS Input Voltage
100
100 90
80 70 60
80 70
LOAD (%)
LOAD (%)
40
60 50 40
20
-10 -10
0 0
10
20
30
40
50
60 (HORIZONTAL)
90
110
115
135
155
230 264
AMBIENT TEMPERATURE (
)
INPUT VOLTAGE (VAC) 60Hz
File Name:TP-100-SPEC 2006-08-22
ELECTRONIC COMPONENTS
RSG
RSG Electronic Components GmbH Sprendlinger Landstr. 115 D-63069 Offenbach/Germany Tel. +49 69 984047-0 Fax +49 69 984047-77 info@rsg-electronic.de www.rsg-electronic.de

Anderungen vorbehalten / subject to change without notice
12.5
25
50
38
99


▲Up To Search▲   

 
Price & Availability of TP-100

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X